Thermal Shock Chamber (Two Room)
DUT is placed inside basket, basket can be moved vertically or horizontally.
By pneumatic cylinder or electrical motor.


Model AZTS100U-2T AZTS150U-2T AZTS200U-2T AZTS300U-2T AZTS500U-2T AZTS1000U-2T
Power Supply AC 380V 50HZ 3 phase+N+PE
Maximum Current (A) 40 50 60 70 90 100
Maximum Power (KW) 20 25 29 35 45 55
Operation Environment +15~+35℃/≤85%RH
Type Two Zone
Basket moving mechanism Pneumatic
Basket moving direction Vertical direction Horizontal direction
Maximum Basket Load 16kg 20kg 30kg 35kg 100kg 130kg
Basket Transfer Time <10S
Performance*1 Temperature Range Cold Zone: -70℃~-10℃, Hot Zone: Amb+20℃~+180℃
Temperature Fluctuation Hot Zone: ±1% of set point or ±1℃, whichever is greater;Cold Zone: ±1℃;
Temperature Deviation ≤±2℃
Test condition with load for 2 minutes recovery time -55℃/+125℃ with 2.5kg Fe -55℃/+125℃ with 5kg Fe -55℃/+125℃ with 10kg Fe -55℃/+125℃ with 15kg Fe -55℃/+125℃ with 25kg Fe -55℃/+125℃ with 50kg Fe
Test condition with load for 5 minutes recovery time -65℃/+150℃ with 0.5kg Fe -65℃/+150℃ with 2.5kg Fe -65℃/+150℃ with 4kg Fe -65℃/+150℃ with 7kg Fe -65℃/+150℃ with 13kg Fe -65℃/+150℃ with 30kg Fe
Inspection Window Multilayer glasses with conducting film heating, size 310mmx240mmx1 Multilayer glasses with conducting film heating, size 470mmx320mmx1
Controller System AZ-1000 controller integrated with Siemens S7 PLC
Temperature Control Mode Independent PID regulation of consecutive cooling and heating capacity
Condenser Air-cooled condenser Air-cooled condenser Water-cooled condenser Water-cooled condenser Water-cooled condenser Water-cooled condenser
Basket Volume (L) 102 148 205 294 506 960
Basket Size W(mm) 510 510 620 700 750 1000
D(mm) 400 580 660 700 750 800
H(mm) 500 500 500 600 900 1200
Exterior Size W(mm) 870 980 1050 1200 3050 3400
D(mm) 2300 2400 2600 2850 1790 2000
H(mm) 2520(1950) 2720(2100) 2720(2100) 3200(2500) 1900 2400
Standard Configuration ● Castors (AZTS100U-2T, AZTS150U-2T, AZTS200U-2T, AZTS300U-2T)
● Lighting
● Inspection window of hot zone
● USB interface and history data review and converting software
● Cable port with silicon plug Φ23mm
● One shelf
Optional Configuration ○ Inspection window of cold zone
○ Water cooled condenser (AZTS64U-2T, AZTS110U-2T)
○ Exterior socket 220V 10A
○ LAN interface and remote control software
○ Digital alarm input channels x 4
○ Auxiliary relay digital output channels x 4 (for specimens)
○ Switching the test zone according to the test specimen surface temperature
○ Additional analog sampling channels x 4, sampling data can be reviewed and recorded (Option: PT100/T thermocouple/4~20mA/0~10V/-10V~10V)
○ Additional analog sampling channels x 8, sampling data can be reviewed and recorded (Option: PT100/T thermocouple/4~20mA/0~10V/-10V~10V)
○ Analog output channels x 3 (Setting high temperature/Setting low temperature/Measured temperature)
○ Compressed dry air purging system
○ Basket driven by electrical motor
*1: All the above specifications are measured at +25℃ room temperature and the sensors are installed at blow-out of air conditioning unit;