Customized product by different volume and change of rate;
Integrated structure, no field installation.
Suitable for large size DUT.


Model*1 AZT(H)2L AZT(H)4L AZT(H)6L AZT(H)8L AZT(H)12L AZT(H)2U AZT(H)4U AZT(H)6U AZT(H)8U AZT(H)12U
Power Supply AC 380V 50HZ 3 phase+N+PE
Maximum Current (AZT/AZTH)(A) 21/27 29/35 37/43 42/48 57/69 28/34 40/46 50/62 59/71 80/92
Maximum Power (AZT/AZTH)(KW) 12/16 17/21 21.5/25.5 24/28 34/42 16/20 23/27 28.5/36.5 34/42 47/55
Cooling Water Requirement (m3/h) 4 5 5 5.5 8 4 5 6 10 12
Operation Environment +15~+35℃/≤85%RH
Control Mode Independent PID regulation of consecutive cooling and heating capacity
(more energy-saving compared with balanced control mode)
Performance*3 Temperature Range -35℃~+120℃ -60℃~+120℃
Relative Humidity Range +10℃~+85℃ 10%~98%RH
Dew Point Range +4℃~+84.5℃
Temperature Fluctuation ≤±0.5℃
Temperature Uniformity ≤2℃
Temperature Deviation ≤±2℃
Humidity Deviation ≤±3%RH
AZT Model Heating Rate*2 3.5 3.2 3.5 2.8 3.2 3.2 3 3.4 2.8 3.2
AZT Model Cooling Rate*2 2.5 2.2 2.2 2.8 3.2 2.8 2.5 2.5 3.2 3.6
AZTH Model Heating Rate*2 3.5 3.2 3.5 2.8 3.2 3.2 3 3.4 2.8 3.2
AZTH Model Cooling Rate*2 3.5 2.2 2.2 2.8 3.2 2.8 2.5 2.5 3.2 3.6
Inspection Window One multilayer glasses with conducting film heating in each door, size W450xH450
Controller System AZ-1000 controller integrated with Siemens S7 PLC
Condenser Water cooled condenser
Humidification Water Supply Self feeding by deionized water
Interior Capacity (m3) 1.98 4.05 5.96 8 12 1.98 4.05 5.96 8 12
Interior Size W(mm) 1100 1800 1900 2000 2000 1100 1800 1900 2000 2000
D(mm) 1200 1500 1850 2000 3000 1200 1500 1850 2000 3000
H(mm) 1500 1500 1750 2000 2000 1500 1500 1750 2000 2000
Exterior Size W(mm) 1400 2100 2200 2300 2300 1400 2100 2200 2300 2300
D(mm) 2650 2950 3300 3450 4550 2650 2950 3300 3450 4550
H(mm) 2170 2170 2420 2670 2670 2170 2170 2420 2670 2670
Door Single wing door Double wing door
W1800mmx
H1500mm
Double wing door
W1900mmx
H1750mm
Double wing door
W2000mmx
H2000mm
Double wing door
W2000mmx
H2000mm
Single wing door Double wing door
W1800mmx
H1500mm
Double wing door
W1900mmx
H1750mm
Double wing door
W2000mmx
H2000mm
Double wing door
W2000mmx
H2000mm
Standard Configuration ● Cable port with silicon plug Φ80mmx1
● Anti-slip floor
● Internal lighting
● Water cooled condenser
● USB interface and history data review and converting software
Optional Configuration ○ Other chamber interior size
○ Other temperature range
○ Cable port with silicon plug Φ50mm/Φ100mm
○ Shelf
○ Air cooled condenser
○ Exterior socket 220V 10A
○ LAN interface and remote control software
○ Remote integration control for multi chambers
○ Digital alarm input channels x 4
○ Auxiliary relay digital output channels x 4 (for specimens)
○ Additional analog sampling channels x 4, sampling data can be reviewed and recorded (Option: PT100/T thermocouple/4~20mA/0~10V/-10V~10V)
○ Additional analog sampling channels x 8, sampling data can be reviewed and recorded (Option: PT100/T thermocouple/4~20mA/0~10V/-10V~10V)
○ Analog output channels x 4 (Setting temperature/Setting humidity/Measured temperature/Measured humidity)
○ Exterior analog input channels control temperature and humidity (Option: 4~20mA, 0~10V, -10V~10V)
○ Compressed dry air purging system
○ Automatic water purification system
○ Temperature control on test specimen
*1: AZT modle has no humidity control cuntion;
*2: Average speed between highest and lowest temperature(without load and heat dissipation according to IEC60068-3-5);
*3: All the above specifications are measured at +25℃ room temperature and the sensors are installed at blow-out of air conditioning unit;